10 WIKA operating instructions models LSO.06, LSO.25
13334603.01 09/2010 GB/D/F/E
3. Specications
GB
3. Specications
3.1 Transducer model LSO.06
General data
Measuring accuracy ±0.5 mm
Ambient light max. 100 Lux
Mounting position any
Weight
■
Standard version
■
High and low temperature version
0.77 kg +9.3 g/cm ML
1)
1.07 kg +9.3 g/cm ML
1)
1) ML = Measuring length
Design data
Medium temperature
■
Standard version
■
High and low temperature version
-65 ... +250 °C
-269 ... +400 °C
Ambient temperature -65 ... +95 °C
Working pressure 0 ... 25 MPa (0 ... 250 bar)
High pressure version 0 ... 50 MPa (0 ... 500 bar)
Materials
■
Sensor case
■
Light guide
■
Packing
■
Case
1.4571 (option: hastelloy, other materials on request)
clad core glass (option: quartz, sapphire (only max.
ML = 60 mm))
graphite
stainless steel
Ex ignition protection type II 1/2 G Ex ib op is IIC T5, T6
T6: to 60 °C, T5: to 75 °C
ZELM 10 ATEX 0440
Electrical data
Cable gland M20 x 1.5, Ex: blue
Terminal connection 3 x 2.5 mm²
Ingress protection IP 65 per EN 60529
For further specications see WIKA data sheet LM 31.10 and the order documentation.