6.5 Menu schematic
Information:
Depending on the version and application, the highlighted menu
windows may not always be available.
Basic adjustment
1
Basic adjustment
Display
Diagnostics
Service
Info
1.1
Unit
Unit of measurement
bar
Temperature unit
°C
1.2
Position correction
Oset
P
=
0.2 mbar
0000 mbar
1.3
Min. adjustment
000.0 %
=
0.0 mbar
0.0 mbar
1.4
Max. adjustment
100.00 %
=
100.00 mbar
0.0 mbar
1.5
Damping
1 s
1.6
Linearisation curve
linear
1.7
Sensor-TAG
Sensor
Display
2
Basic adjustment
Display
Diagnostics
Service
Info
2.1
Displayed value
Pressure
2.1
Displayed value
Scaled
2.2
Display unit
Volume
l
2.3
Scaling
0 % = 0.0
l
100 % = 100.0
l
2.4
Lighting
Switched o
30 Process pressure transmitter IPT-1* Vers. 3.0 - metalic sensor 4 20 mA