3. Specications
3.4 Voltage supply
Power supply
DC 15 ... 35 V
Current consumption
max. 100 mA
Total current consumption
max. 600 mA (incl. switching current)
3.5 Measuring element
Resistance measuring chain with reed switches and float
Resolution
< 6 mm
Response time
< 700 ms
Maximum working pressure
3 bar
Media compatibility
Test following ISO 7620, section 6, table 1
Medium Standard
Mineral oil HLP per DIN 51524
Aqueous solution HFC per VDMA 24317
Organic ester HFD-U per VDMA 24317
Triglyceride (rape oil) HETG per VDMA 24568
Synthetic ester HEES per VDMA 24568
Polyglycols HEPG per VDMA 24568