27WIKA operating instructions pressure switch model PSA-31
GB
14018458.01 11/2011 GB/D/F/E
6. Commissioning, operation
Index
(decimal)
Object name Value Remarks
2 RES 130 Return the set parameter to the factory settings
2 LOCK 163 General keylock On
2 UNLOCK 164 General keylock O
2 RHL 176 Clear the Min- and Max-value memories
2 0SET 177 Zero-point adjustment (3 % of span) see page 17
Index
(decimal)
Object
name
Format Access Value range Factory set-
ting
Remarks
240 MBA 32 Bit IEEE
754 Float
R - 1,000 The pressure value is
always linearised such
that the MBA equals the
value 1,000 and the MBE
equals the value 9,000.
241 MBE 32 Bit IEEE
754 Float
R - 9,000 The pressure value is
always linearised such
that the MBA equals the
value 1,000 and the MBE
equals the value 9,000.
250 DISR 8 Bit
Enumeration
R/W 0 = Standard
1 = 180° rotated
0 Turn display indicator
by 180°
251 DISM 8 Bit
Enumeration
R/W 0 = Act
1 = HIGH
2 = LOW
3 = SP1/FH1
4 = RP1/FL1
5 = SP2/FH2
6 = RP2/FL2
7 = O
0 Display value in display
mode
252 PAS 16 Bit
unsigned
R/W 0 … 9,999 - Enter password in order
to set the parameters at
the instrument. Password
0 = no password
253 LOCK 8 Bit
Enumeration
R/W 0 = Unlocked
1 = Locked
0 General keylock